PCB Transformer

Home >  Products >  PCB Transformer

220V 230V to 6V 9V 12V 24V Encapsulated PCB Power Transformer

Compact encapsulated transformer for direct PCB mounting, suitable for electronic controls, monitoring systems, smart devices and industrial power supply modules.

Parameter Typical Range / Available Options
Product Type Low-frequency encapsulated PCB-mount transformer
Construction EI laminated core, copper windings, insulated bobbin, protective enclosure and resin encapsulation
Rated Power Typically 0.5 VA to 60 VA; other ratings subject to engineering review
Primary Voltage 100 V, 110 V, 115 V, 120 V, 127 V, 200 V, 208 V, 220 V, 230 V or 240 V AC
Dual Primary Options 2 × 115 V, 2 × 120 V or other series/parallel configurations
Secondary Voltage Typically 3 V to 48 V AC; custom voltage available
Secondary Configuration Single, dual, center-tapped or multiple independent windings
Frequency 50 Hz, 60 Hz or 50/60 Hz
Output Type Isolated AC output
Core Material Laminated electrical steel selected according to power, loss and temperature-rise requirements
Winding Material Specified-grade enameled copper wire
Dielectric Strength Commonly designed within a 3,000–4,000 VAC range; final voltage and test duration depend on the approved insulation system and applicable standard
Insulation Resistance Commonly ≥100 MΩ at 500 V DC; final acceptance criteria according to the approved specification
Insulation Class Class B 130°C or Class F 155°C options
Temperature Rise Defined according to rated load, ambient temperature, enclosure condition and applicable standard
Voltage Regulation Optimized according to output voltage, load current, size and temperature-rise requirements
Encapsulation Flame-retardant epoxy or other resin system selected according to project requirements
Housing Standard or custom molded enclosure; flame-retardant material options available
Mounting Through-hole PCB mounting
Pin Layout Standard or fully customized pin spacing and pin assignment
Protection Options Thermal fuse, PTC protection, current-limiting design or short-circuit-resistant design where required
Shielding Options Electrostatic shield between primary and secondary windings
Compliance Options IEC/EN 61558, UL 5085, CE, UL/cUL, RoHS and REACH requirements, subject to model and project scope
Marking Model number, electrical rating, date code, batch code, customer logo or private label
Packaging Individual partitions, trays, cartons and export pallets
  • Overview
  • Recommended Products

Encapsulated PCB Transformer Specifications

The values above represent common design options rather than the guaranteed specification of every model. Final electrical ratings, dimensions, test limits and compliance requirements are defined in the ECKO-approved product specification and dimensional drawing.

397f6e699f7dcc58c518414719dafbbd.jpeg

Key Advantages of ECKO Encapsulated PCB Transformers

1. Resin-Encapsulated Protection

The resin encapsulation immobilizes the windings and internal structure, helping protect the transformer against dust, humidity, vibration and handling damage. It also improves mechanical stability during PCB assembly and long-term equipment operation.

Encapsulation alone does not make the transformer waterproof. Outdoor, washdown or high-condensation applications require a separate environmental and IP protection assessment.

2. Compact PCB-Mount Design

The enclosed construction combines electrical isolation and voltage conversion in a space-efficient through-hole component. Customized pin layouts help reduce wiring, simplify assembly and fit the available PCB footprint.

3. Stable Voltage and Thermal Performance

The core, winding turns, copper wire size and insulation structure are designed around the actual input range, output load and operating environment. This helps achieve controlled voltage regulation, no-load current, losses and temperature rise.

4. Application-Specific Electrical Isolation

Basic, supplementary or reinforced insulation can be considered according to the end-product architecture and applicable safety standard. Creepage distance, clearance, insulation tape, bobbin construction and dielectric test requirements are reviewed during development.

5. Reduced Mechanical and Acoustic Noise

Resin encapsulation helps limit movement of the core and windings. Combined with controlled core assembly and production processes, it supports stable and low-noise operation in control, instrumentation and indoor electronic equipment.

6. Consistent PCB Assembly

Controlled pin positioning, enclosure dimensions and final inspection improve compatibility with automated or manual PCB assembly. Every approved model is manufactured against controlled drawings, material specifications and electrical test limits.


Custom Encapsulated PCB Transformer Options

Electrical Customization

  • Primary input voltage and input tolerance
  • Single or dual primary windings
  • Single, dual, center-tapped or multiple secondary outputs
  • Rated power and secondary current
  • No-load voltage and full-load voltage
  • Voltage regulation target
  • No-load current and power-loss requirements
  • 50 Hz, 60 Hz or universal 50/60 Hz operation
  • Basic or reinforced isolation
  • Maximum allowable temperature rise
  • Continuous, intermittent or application-specific duty cycle

Mechanical Customization

  • Maximum length, width and height
  • PCB pin pitch and row spacing
  • Pin diameter, pin length and pin assignment
  • Horizontal or vertical PCB-mount construction
  • Customer PCB footprint
  • Enclosure shape, material and color
  • Marking position and orientation
  • Customer-specific dimensional tolerances

Insulation and Protection Options

  • Class B or Class F insulation system
  • Thermal fuse embedded in the primary winding
  • Resettable PTC protection
  • Electrostatic shield with a dedicated grounding pin
  • Increased dielectric withstand capability
  • Increased creepage and clearance distance
  • Short-circuit-resistant design where technically applicable
  • Special resin for temperature, humidity or vibration requirements

Compliance and Identification

  • IEC/EN or UL-oriented construction
  • RoHS- and REACH-compliant material options
  • UL-recognized insulation materials where required
  • Customer logo and private labeling
  • Model number, lot number and date-code marking
  • Barcode or serialized traceability
  • Customer-specific inspection reports and compliance documents

Encapsulated PCB Transformer Applications

ECKO encapsulated PCB transformer provide compact AC voltage conversion and electrical isolation for industrial, commercial and consumer electronic assemblies. Each transformer can be customized around the PCB footprint, load profile, operating temperature and safety requirements of the end product.

Industrial Control and Automation

Supplies isolated low-voltage AC power for PLC interfaces, relays, contactors, timers, sensors and auxiliary control circuits inside industrial controllers and automation equipment.

HVAC and Building Controls

Suitable for thermostats, ventilation controllers, boiler controls, access systems and building automation boards requiring a compact board-mounted transformer.

Smart Meters and Energy Management

Provides isolated auxiliary power for metering circuits, monitoring devices, energy controllers and power-management electronics.

Security and Access Control Equipment

Can be designed for alarm panels, access controllers, intercom systems and other low-voltage security electronics, subject to the approval requirements of the complete end product.

Household and Smart-Home Appliances

Supports control boards used in kitchen appliances, environmental controls, smart-home devices and other mains-powered electronic products.

Test and Measurement Equipment

Delivers isolated AC power for instrumentation, laboratory controllers and measurement circuits. An electrostatic shield can be added when improved capacitive noise isolation is required.

Lighting and LED Control Systems

Suitable for lighting controllers, timers, relay boards and auxiliary power circuits that require reliable isolation from the mains input.

Communication and Electronic Control Boards

Provides compact board-level power conversion for communication terminals, interface modules and electronic controllers requiring a line-frequency isolated power source.

Why Choose ECKO as Your Encapsulated PCB Transformer Manufacturer?

Engineering Design Based on Your Actual Application

ECKO does not select a transformer only by input voltage and VA rating. Our engineering review considers:

  • Input voltage range and frequency
  • Continuous and peak secondary load
  • Required no-load and full-load voltage
  • Voltage regulation
  • Core flux density
  • Copper loss and core loss
  • Temperature-rise limit
  • Insulation structure
  • Creepage and clearance distance
  • PCB footprint and enclosure restrictions
  • End-product safety and compliance requirements
  • The resulting design is balanced for electrical performance, thermal behavior, manufacturability and cost.

Revision-Controlled Technical Documents

Every customized model is managed through controlled technical documentation, which may include:

  • Customer requirement sheet
  • Approved electrical specification
  • Dimensional and pin-layout drawing
  • Bill of materials
  • Winding specification
  • Insulation construction
  • Process instructions
  • Approved test limits
  • Sample approval record
  • Engineering change record

Drawing, specification and material revisions are identified before production. Changes affecting form, fit, function, safety or approved materials are reviewed through the engineering change process instead of being introduced without control.

Controlled Raw Materials

ECKO uses specified-grade enameled copper wire, electrical steel laminations, bobbins, insulation materials, housings, pins and encapsulating resin from controlled sources.

Incoming materials are checked according to the applicable inspection plan. Material grade, dimensions, appearance and compliance documentation can be included in the control process according to project requirements.

Integrated Manufacturing Capability

With transformer manufacturing experience since 2000, ECKO operates three workshops covering approximately 5,000 m², supported by around 150 skilled employees and an annual production capacity of up to one million pieces.

Our production capability covers winding, termination, core assembly, resin dispensing, curing, marking, electrical testing, final inspection and export packaging. This integrated workflow supports prototype development as well as repeat-volume production.

Traceable Quality Control

Approved models are manufactured according to controlled drawings, work instructions and test limits. Lot identification, material records and test documentation can be maintained according to the agreed quality plan.

Routine electrical tests are performed before shipment, while temperature rise, overload behavior and environmental tests are completed during qualification or according to customer-specific inspection requirements.


Testing Items and Acceptance Standards

From winding continuity and output voltage to insulation withstand, temperature rise and solderability, ECKO verifies each PCB transformer according to the approved drawing, test specification and inspection plan.

Routine Production Tests

pcb-transformer-dimensional-inspection-1200x900.jpg

Visual and Dimensional Inspection

Workmanship, labels, polarity marks, pin condition, outline dimensions, seated height, pin pitch and pin position are checked against the approved drawing.

  • Visual Inspection: Routine or sampling
  • Dimensional Inspection: Sampling, with critical dimensions controlled as specified

pcb-transformer-output-voltage-test-1200x900.jpg

Winding and Output Verification

Winding resistance testing checks conductor continuity and manufacturing consistency. Turns-ratio and output-voltage testing confirm the required secondary voltage and winding polarity at the specified primary input.

  • Winding Resistance: Routine test
  • Turns Ratio / Output Voltage: 100% routine test

220v 230v to 6v 9v 12v 24v encapsulated pcb power transformer-0

No-Load and Rated-Load Performance

No-load current and no-load loss are evaluated to confirm core assembly, winding consistency and standby performance. Rated-load voltage and regulation are verified under defined input and load conditions.

  • No-Load Current: 100% or agreed inspection plan
  • No-Load Loss: Sampling or qualification
  • Load Voltage and Regulation: Sample and periodic verification

220v 230v to 6v 9v 12v 24v encapsulated pcb power transformer-1

Insulation Safety Testing

Insulation resistance testing checks electrical separation between windings and accessible conductive parts. Dielectric strength testing verifies the specified insulation withstand level at the approved voltage and duration.

  • Insulation Resistance: Routine or sampling
  • Dielectric Strength / Hi-Pot: 100% at the approved test level

220v 230v to 6v 9v 12v 24v encapsulated pcb power transformer-0

Temperature Rise and Audible Noise

Temperature-rise testing verifies thermal performance under defined mounting, ambient and load conditions. Audible-noise evaluation is performed when transformer hum or mechanical vibration is controlled by the project specification.

  • Temperature Rise: Type or qualification test
  • Audible Noise: When required by the approved specification

220v 230v to 6v 9v 12v 24v encapsulated pcb power transformer-3

PCB Pin Solderability

PCB pin wetting and resistance to soldering heat are evaluated to support stable PCB assembly and repeatable solder-joint quality.

  • Solderability: Qualification or sampling
  • Resistance to Soldering Heat: Verified according to the project requirement


Custom Encapsulated PCB Transformer Development Process

Step 1: Submit Your Requirements

Provide the input voltage, frequency, output voltage and current, power rating, PCB footprint, maximum dimensions, operating environment and target compliance requirements.

Step 2: Engineering Feasibility Review

ECKO evaluates the electrical loading, core size, winding arrangement, insulation structure, temperature rise, pin layout and manufacturability.

Step 3: Design Proposal and Quotation

We provide the proposed electrical configuration, mechanical solution, commercial quotation, tooling requirement if applicable and estimated development schedule.

Step 4: Specification and Drawing Approval

The electrical specification, outline dimensions, pin assignment, tolerances, test limits, marking and protection features are confirmed before sample production.

Step 5: Prototype Manufacturing

Samples are manufactured according to the approved development documents. Critical electrical and mechanical characteristics are inspected before shipment.

Step 6: Sample Testing and Customer Approval

The customer evaluates the samples in the actual PCB and end equipment. Any required design adjustments are reviewed, documented and verified.

Step 7: Pilot Production

A pilot run can be arranged to verify production repeatability, assembly compatibility, material control and test consistency before volume production.

Step 8: Mass Production and Shipment

Mass production is completed according to the approved specification, BOM, process instructions and inspection plan. Final products are tested, packed and shipped with the agreed documents.


Encapsulated PCB Transformer FAQ

1. What tests are performed on encapsulated PCB transformers?

Typical tests may include winding resistance, turns ratio, no-load voltage, load voltage, no-load current, insulation resistance, dielectric withstand, polarity, temperature rise, and appearance inspection.

2. Do you test every transformer before shipment?

Critical electrical parameters can be tested according to the approved inspection standard. Production inspection requirements are established according to the product specification and customer requirements.

3. How do you control output voltage consistency?

Output voltage consistency is controlled through winding turns control, wire specifications, production process control, calibrated test equipment, and final electrical inspection.

4. How is winding consistency controlled?

Winding parameters are controlled by production documents specifying wire diameter, turns, winding direction, insulation material, and winding sequence.

5. Do you perform temperature-rise testing?

Yes. Temperature-rise testing can be conducted under specified input voltage, load condition, ambient temperature, and test duration during product validation.

6. Can you provide test reports?

Yes. Relevant inspection or validation records can be supplied when agreed as part of the project requirements.

7. How is insulation resistance tested?

Insulation resistance is measured using appropriate test equipment at the specified DC test voltage between electrically isolated parts.

8. How do you prevent incorrect winding connections?

Winding polarity, pin arrangement, and electrical connections are controlled through approved drawings, production instructions, in-process inspection, and electrical testing.

9. Is the encapsulation process inspected?

Yes. Potting material preparation, filling, curing, appearance, and encapsulation quality are controlled according to defined production procedures.

10. Can special reliability tests be arranged?

Yes. Additional testing can be discussed based on the application, including extended load testing, thermal testing, vibration testing, or other customer-defined validation requirements.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000
inquiry

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000