PCB Transformer

Home >  Products >  PCB Transformer

PCB Transformer Manufacturer for Custom OEM Applications

ECKO designs and manufactures PCB-mounted transformers based on your electrical requirements, dimensional limits and applicable safety standards.

Parameter Typical Range / Available Options
Product Type Open-frame, vacuum-impregnated or fully encapsulated PCB transformer
Rated Power 0.5 VA to 20 VA typical; higher ratings subject to engineering review
Primary Voltage 100V, 110V, 115V, 120V, 200V, 220V, 230V or 240V AC; single or dual primary
Secondary Voltage 3V to 48V AC per winding typical; other voltages available
Output Configuration Single, center-tapped, dual or multiple secondary windings
Frequency 50Hz, 60Hz or 50/60Hz
Core Material EI laminated electrical steel core selected according to power and temperature-rise requirements
Winding Material Copper winding wire
Insulation Class Class B 130°C or Class F 155°C
Dielectric Strength Project-specific; 3.0–4.0kVAC primary-to-secondary options commonly available
Temperature Rise Defined according to rated load, ambient temperature, enclosure and insulation class
Pin Configuration Custom pin count, pitch, row spacing, diameter, length and polarity marking
Protection Options Thermal fuse, resettable thermal protector or external PTC coordination
  • Overview
  • Recommended Products

Custom PCB Transformers Engineered for Your Circuit Board

Compact through-hole PCB transformers with customized input voltage, output windings, rated power, pin layout and insulation construction. ECKO designs each transformer around your load requirements, PCB footprint, temperature-rise target and applicable safety requirements.

From initial electrical calculations to approved drawings, controlled production and routine electrical testing, we help OEM customers integrate reliable mains-frequency power conversion directly into their PCB assemblies.

Typical PCB Transformer Specifications

Custom PCB Transformers Engineered for Your Circuit Board

Specification notice: The values above represent typical engineering capabilities rather than one fixed catalog model. Final electrical ratings, dimensions, tolerances and test limits are defined by the customer-approved specification and dimensional drawing.

PCB Transformer Product Advantages

PCB Footprint Designed Around Your Board

Pin spacing, row distance, pin diameter, seated height and maximum external dimensions can be developed from your PCB layout. This helps reduce board redesign and improves first-fit integration during prototype assembly.

Stable Output Under Actual Load Conditions

The transformer is calculated according to the required output voltage, current, duty cycle and acceptable regulation. Output performance is verified under the agreed input voltage, frequency and rated-load conditions.

Controlled Temperature Rise

Core size, magnetic flux density, copper current density, winding arrangement and insulation materials are selected together. This provides a practical thermal margin for enclosed control boards and continuously operated equipment.

Low No-Load Current and Reduced Core Loss

The number of turns, core stack and operating flux density are optimized for the specified mains frequency. This helps control standby loss, excitation current and unnecessary heating.

Application-Specific Insulation Design

The bobbin, winding barriers, insulation tape, creepage distance, clearance distance and dielectric-strength level are reviewed according to the end-product requirements. Functional, basic, supplementary or reinforced insulation can be evaluated.

Quiet and Repeatable Production

Controlled winding tension, core assembly, impregnation or encapsulation help reduce mechanical vibration and audible hum. Approved drawings, BOMs and test limits improve consistency between samples and production batches.

PCB Transformer Customization Options

01-electrical-input.png

Electrical Input

02-electrical-output.png

Electrical Output

03-rated-power.png

Rated Power

05-pcb-footprint.png

PCB Footprint

06-product-dimensions.png

Product Dimensions

07-insulation-system.png

Insulation System

08-dielectric-strength.png

Dielectric Strength

09-thermal-protection.png

Thermal Protection

11-environmental-protection.png

Environmental Protection

12-noise-control.png

Noise Control

14-documentation.png

Documentation

15-packaging.png

Packaging

Why Choose ECKO for Custom PCB Transformers?

Engineering Design Based on the Complete Application

ECKO evaluates the input range, frequency, output load, voltage regulation, temperature rise, PCB space, enclosure ventilation and insulation requirements before releasing a design. The transformer is developed as part of the customer’s power circuit rather than selected only by voltage and VA.

Controlled Specifications, Drawings and Revisions

Each approved project can be managed through a controlled product specification, dimensional drawing, pin diagram, BOM, process instruction and inspection plan. Engineering changes are recorded by revision, approval status and effective production lot.

Qualified and Traceable Raw Materials

Copper wire, electrical steel, bobbins, insulation tape, thermal protectors, terminals and encapsulation materials are purchased according to approved specifications. Incoming inspection and batch records help prevent unauthorized material substitution.

Production Capacity with Process Control

Established in 2000, ECKO operates three workshops covering approximately 5,000m² with around 150 skilled workers. Winding, soldering, core assembly, impregnation, encapsulation and electrical testing are managed through defined production and inspection procedures.

Quality Control from Sample to Mass Production

Critical electrical parameters are confirmed during sample verification and transferred into the production test specification. Routine testing and batch traceability support stable repeat orders and more efficient customer incoming inspection.

PCB Transformer Tests and Reference Standards

From winding continuity and output voltage to insulation withstand, temperature rise and solderability, ECKO verifies each PCB transformer according to the approved drawing, test specification and inspection plan.

Routine Production Tests

pcb transformer manufacturer for custom oem applications-0

Visual and Dimensional Inspection

Workmanship, labels, polarity marks, pin condition, outline dimensions, seated height, pin pitch and pin position are checked against the approved drawing.

  • Visual Inspection: Routine or sampling
  • Dimensional Inspection: Sampling, with critical dimensions controlled as specified

pcb-transformer-output-voltage-test-1200x900.jpg

Winding and Output Verification

Winding resistance testing checks conductor continuity and manufacturing consistency. Turns-ratio and output-voltage testing confirm the required secondary voltage and winding polarity at the specified primary input.

  • Winding Resistance: Routine test
  • Turns Ratio / Output Voltage: 100% routine test

pcb transformer manufacturer for custom oem applications-1

No-Load and Rated-Load Performance

No-load current and no-load loss are evaluated to confirm core assembly, winding consistency and standby performance. Rated-load voltage and regulation are verified under defined input and load conditions.

  • No-Load Current: 100% or agreed inspection plan
  • No-Load Loss: Sampling or qualification
  • Load Voltage and Regulation: Sample and periodic verification

pcb transformer manufacturer for custom oem applications-2

Insulation Safety Testing

Insulation resistance testing checks electrical separation between windings and accessible conductive parts. Dielectric strength testing verifies the specified insulation withstand level at the approved voltage and duration.

  • Insulation Resistance: Routine or sampling
  • Dielectric Strength / Hi-Pot: 100% at the approved test level

pcb transformer manufacturer for custom oem applications-1

Temperature Rise and Audible Noise

Temperature-rise testing verifies thermal performance under defined mounting, ambient and load conditions. Audible-noise evaluation is performed when transformer hum or mechanical vibration is controlled by the project specification.

  • Temperature Rise: Type or qualification test
  • Audible Noise: When required by the approved specification

pcb transformer manufacturer for custom oem applications-4

PCB Pin Solderability

PCB pin wetting and resistance to soldering heat are evaluated to support stable PCB assembly and repeatable solder-joint quality.

  • Solderability: Qualification or sampling
  • Resistance to Soldering Heat: Verified according to the project requirement

Custom PCB Transformer Development Process

Step 1: Submit the Application Requirements

Provide the primary voltage, frequency, secondary voltage and current, available PCB space, operating environment, annual quantity and applicable safety requirements.

Step 2: Engineering Feasibility Review

ECKO reviews the VA requirement, winding arrangement, core size, temperature-rise target, insulation construction, PCB footprint and potential technical risks.

Step 3: Technical Proposal and Quotation

We provide a proposed electrical configuration, construction type, estimated dimensions, testing plan, tooling requirements and commercial quotation.

Step 4: Specification and Drawing Approval

The customer reviews the electrical specification, outline drawing, PCB footprint, pin assignment, polarity and critical tolerances before sample production.

Step 5: Prototype Manufacturing

Samples are produced using the approved materials and process route. Electrical and dimensional test records can be provided according to the agreed project plan.

Step 6: Sample Verification and Customer Approval

Output voltage, load regulation, no-load current, temperature rise, dielectric strength, dimensions and PCB fit are confirmed before production release.

Step 7: Controlled Mass Production

The approved BOM, drawing revision, winding data, process instructions and test limits are released to production. Routine tests and batch identification are applied according to the inspection plan.

PCB Transformer FAQ

1. What information is required to quote a custom PCB transformer?

Please provide the input voltage and frequency, each output voltage and current, rated power or load profile, maximum dimensions, PCB footprint, operating temperature, insulation requirements, annual quantity and applicable safety standard. A PCB file, existing drawing or product sample is also helpful.

2. How do I calculate the required transformer VA rating?

For each secondary winding, multiply the rated output voltage by the required output current. Add the VA values of all windings and include suitable design margin for regulation, temperature rise, intermittent peak loads and rectifier circuits.

3. Can you produce 115V/230V dual-primary PCB transformers?

Two primary windings can be configured for series or parallel connection to support different mains voltages. The pin assignment, connection diagram and insulation requirements must be confirmed on the approved drawing.

4. Can one PCB transformer provide multiple output voltages?

We can design single, dual, center-tapped or multiple independent secondary windings. Please specify the voltage, current and duty cycle required from each winding.

5. What is the difference between an open-frame and an encapsulated PCB transformer?

An open-frame transformer is generally smaller, lighter and more economical. A fully encapsulated transformer provides better protection against moisture, dust and mechanical vibration, but normally has different thermal behavior, dimensions and tooling requirements.

6. Can you match our existing PCB footprint?

We can review your PCB layout, hole positions, keep-out area and maximum component height. Final pin tolerances and PCB hole diameters should be confirmed through an approved dimensional drawing.

7. Can the transformer dimensions be customized?

Within the limits of electrical power, insulation distance, core size and temperature rise. Reducing one dimension may require increasing another dimension or accepting different thermal and regulation performance.

8. What is the typical temperature rise of a PCB transformer?

Temperature rise is not one fixed value for every model. It depends on the VA rating, ambient temperature, enclosure ventilation, core flux density, winding current density and insulation class. ECKO can design to an agreed maximum temperature-rise target and verify it on the sample.

9. Can you reduce no-load current, standby loss or audible hum?

Yes. These characteristics can be improved through core selection, increased turns, lower flux density, controlled core assembly, winding arrangement and impregnation. The required limits should be stated before the transformer size and price are finalized.

10. Can you add an electrostatic shield?

A shield can be placed between the primary and secondary windings to reduce capacitive coupling and common-mode noise. The shield lead and grounding method must be shown in the customer’s circuit and pin diagram.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000
inquiry

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000