transformator industrialis pro tensione controllo 220V, 380V et 415V
Configurable AC input taps and 12V, 24V, 48V, 110V or customized outputs for international industrial equipment.
Custom BK control transformers for industrial control panels, machine tools and automation equipment. Configure voltage, VA rating, terminals, mounting and protection.
- Conspectus
- Producta Commendata
- Designatus pro onere continuo et onere momentaneo inrush VA
- Singuli aut multi taps tensionis input
- Singulae, centraliter-tactae aut multiæ spirales output
- designationes 50 Hz, 60 Hz aut 50/60 Hz
- Blocchi terminalium personalizati, fili ductiles et connectores
- Spirales cupreas disponibiles
- Insulatio classis B, F aut H
- Dimensiones et interstitia foraminum ad mensuram
- Fusibilis, protector thermalis et scutum electrostaticum (optio)
- Inspectio electrica et de securitate cotidiana antequam mittatur
- 110 VAC
- 120 VAC
- 220 VAC
- 230 Vac
- 240 VAC
- 380 VAC
- 400 VAC
- 415 VAC
- 440 VAC
- 480 VAC
- Tensio introducta a cliente specificata
- 6 VAC
- 12 VAC
- 24 VAC
- 36 VAC
- 48 VAC
- 110 VAC
- 220 VAC
- Plures exirentes isolati
- Exitus centraliter divisi
- Tensio et intensitas a cliente specificatae
- Onus VA continuatum
- Onus VA inrusionis contactoris aut retractoris
- Onus VA bobinae hermeticis
- Numerus dispositivorum controlis connexorum
- Ordo commutationis simulanea
- Officium intermittens aut continuatum
- Tensio minimā acceptābilis ad incipiendum
- Cadēns tensiō admīssibilis sub plēnō onere
- Classis B Isolatio
- Classis F Isolatio
- Isolatio Classis H
- Fusus primarius
- Fusibīlis secundārius
- Protector thermicus ūnīcās usūs
- Protector thermicus rēmittendus
- Scutum electrostaticum
- Terminus terrae
- Insulātiō āctiōr in spatiō inter vīndingēs prīmāriās et secundāriās
- Blox terminālia tāctū sēcūra
- Fistulae fixationis
- Fila directrices
- Terminales Faston
- Conectores especificados por el cliente
- Numeración de terminales
- Schema electrica
- Dirección y espaciamiento de terminales
- Dimensiones totales del transformador
- Altura máxima de instalación
- Diseño de soporte de montaje
- Espaciamiento entre orificios de montaje
- Foramina de montajus fissurata aut rotunda
- Core Size
- Terminalis Orientatio
- Positio tituli
- Directio installationis
- Specificatio Producti
- Diagramma connexorum electricorum
- Raportus exemplaris approbatus
- Rapportum Inspectionis
- Declaratio materialium
- Documentatio RoHS aut CE
- Documentatio conformitatis pro modello specificato
- Inspection del core, filo, bobina e insulatione in ingressu
- Inspection del processo de avolutione
- Verification del filo conductor e del terminal
- Montage del core e inspection mechanice
- Examinatio Electrica Praestantiae
- Test de resistentia del insulatione
- Test de sustentation dielectrica
- Inspection finalis del dimensiones, etiquetta e impachettamento
- Voltage input
- Frequency
- Output Voltage et current
- VA Continua
- VA Inrumpens et VA Sigillata
- Type onus
- Ordo Commutandi
- Cyclum officii
- Ambiens Temperature
- Dimensiones maximae
- Distantia Foraminum Montandi
- Requisitiones Terminalium
- Lorem signa
- Quantitas Annuale Coniecta
- Electrical Ratings
- Dimensionum totalium
- Espaciamiento entre orificios de montaje
- Numeración de terminales
- Schema wiring
- Informationes de etiquetta
- Requisita Materialia
- Requirimenta experimentorum
- Adaptationem mechanicam
- Accessibilitatem terminalium
- Output Voltage
- Captationem contactoris aut solenoidei
- Temperatura operativa
- Strepitus et Vibratio
- Praestantiam totius apparatus
Transformator BK ad personam pro tabulis regulandis industrialibus et machinis utensilibus
Potentia AC pro Controllatione, ad Applicationem Adaptata, pro Contactatoribus, Relais, Circuitibus Auxiliaribus PLC, Solenoidibus, Frenis Electromagneticis et Armariis Controlis Industrialibus.
ECKO BK regulatio transformatores designati sunt ut convertant praecipuum suppeditationem electricam alternantem in stabilem tensionem regulandam pro instrumentis industrialibus.
Nos personalizamus tensionem input, tensionem output, notam VA, frequentionem, systema insulationis, dispositionem terminalium, bracchium fixationis et componentes protectionis secundum requisita apparatus tuorum.
Claves Producti Caracteres:
Specificatio transformatoris de regula
| Parameter | Optiones normales et ad mensuram |
|---|---|
| Nomen Producti | Transformator controlis |
| Ingressus referentiae | 220 VAC aut ad mensuram |
| Egressus referentiae | 12 VAC / 4.17 A |
| Typical Custom Power Range | 25 VA–5 kVA |
| Input Voltage Options | 110 V, 120 V, 220 V, 230 V, 240 V, 380 V, 400 V, 415 V, 440 V or 480 VAC |
| Output Voltage Options | 6 V, 12 V, 24 V, 36 V, 48 V, 110 V, 220 VAC or customized |
| Frequency | 50 Hz, 60 Hz or 50/60 Hz |
| Phasis | Singula Phasium |
| Genus Nuclei | EI laminated silicon-steel core |
| Materia curva | Copper winding available according to the approved specification |
| Insulatio Classis | Class B, Class F or Class H |
| Configuratio Output | Output unus, output centrum-tactus aut outputs isolatos multiplices |
| Optiones terminalium | Blocus terminalis, terminalis vittatus, lamina Faston, filum ductile aut connexor ad usum specialem |
| Modus montandi | Mons pedalis, mons chassidis aut mons ad usum specialem |
| Optiones Protectionis | Fusibilis, protector thermalis, scutum electrostaticum et terminalis terrae |
| Applicatio | Panella de controllo, instrumenta machinalia, apparatus automationis, systemata HVAC et circuitus de controllo motoris |
| Supportus pro conformitate | CE, CQC, RoHS suffragium, secundum exactum modelum et constructionem |
| Experientia | Examinatio functionis electricae et securitatis secundum planum inspectionis approbatum |
Nota: Specificatio supradicta productum referentiam et facultates communis personalizationis describit. Tensio finalis, potentia, dimensiones, augmentum temperaturae, protectio, conditiones examinis et requisita conformitatis in schemate technico approbato confirmabuntur.
Constructus pro veris exigentiis circuituum industrialium de controllo
1. Designed for Coil Inrush and Continuous LoadRecommended Detail Image: Close-up of the transformer coil and winding area. Control devices such as contactors, solenoids and electromagnetic brakes can draw several times their normal current during pickup. ECKO evaluates both momentary inrush VA and continuous sealed VA to help maintain sufficient secondary voltage during switching. |
2. Frequency-Correct EI Laminated CoreRecommended Detail Image: Close-up of the stacked EI silicon-steel laminations. The EI laminated core is selected according to the rated voltage, frequency, power and temperature-rise requirement. Correct magnetic design helps control no-load current, audible noise, core loss and operating temperature. |
3. Accessible and Clearly Arranged TerminalsRecommended Detail Image: Close-up of the orange finger-safe terminal blocks. Terminal-blocks tutelatos ad digitos simplificant connexiones in tabula de controllo et manutentionem futuram. Quantitas terminalium, numeratio, directio, spatium inter eos, et notae tensionis possunt adaptari ad diagramma connexionum clientis. |
4. Systema Isolationis Adaptatum Ad ApplicationemImago Recommandata: Imago propinqua avolutorum isolatorum, bobinae, et fasciae isolationis. Materia bobinae, fascia isolationis, vernix, distantia per superficiem et distantia per aerem seliguntur secundum tensionem operativam et requisita apparatus finalis. Systemata isolationis Classis B, Classis F, et Classis H disponibilia sunt. |
5. Bracchium Montagii Forte et AdaptabileImago Recommandata: Imago propinqua bracchii metallici et foraminum montagii fissorum. Cornu metallicum sustinet installationem stabilem in chassio et dispersionem caloris efficacem. Dimensiones totales, forma bracchii, distantia inter foramina montagii, et directio terminalium possunt adaptari ad installationem intra spatium arctum armarii. |
6. Identificatio Producti RegulataImago detallata recommendata: Vicinissima del etiquetta del transformator et diagramma de terminales. Le etiquetta approbata pote mostrar le tensione de entrata, le tensione de exsita, le frequentia, le potentia nominal, le mappa de terminales e le numero de parte del cliente. Codices de lotto, numeros de serie e simbolos de connexion personalisate es anque disponibile pro le traciabilitate del producto. |
Optiones Personalizandi
Transformatores de control personalisate pro tu apparatos
ECKO provide personalisation electric, mechanic e de documentacion pro clientes OEM, fabricantes de panes de control e productores de apparatos industrial.
Personalisation del tensione de entrataLe tensiones de entrata disponibile include: Plurimi primarii circuitus ad differentes nationes vel conditiones tensionis retis adaptandi designari possunt. |
Adaptatio Tensionis ExeuntisCommuniores tensiones exeuntes sunt: |
Potentia et onus ad usum accommodatumTransformator secundum sequentia designari potest: |
Optiōnēs pro insulātiōne et prōtectiōneOptiones adhiberi possunt hae: |
Optiōnēs pro terminālibus et connexiōnibusPossumus adaptare: |
Customizatio MechanicaOpciones mecánicas incluyen: |
Optiones documentorumSecundum projectum, ECKO praebere potest: |
Transformatoris regulantes pro commutatione industriali et potentia auxiliari
Transformator de control oferă o tensiune alternativă dedicată pentru dispozitivele industriale de comutare și circuitele auxiliare. El poate oferi, de asemenea, izolare galvanică între alimentarea principală și circuitul de comandă, atunci când se folosesc înfășurări primare și secundare separate.
Armarii Controllo Industrialistransformatorii de control sunt instalati frecvent in interiorul cabinetelor electrice de comanda pentru a alimenta releele, temporizatoarele, bobinele contactorilor, circuitele indicatoare si alte componente de comanda. Tensiunea de intrare poate fi adaptată la tensiunea de rețea a fabricii, în timp ce tensiunea de ieșire poate fi personalizată la 12 V, 24 V, 48 V, 110 V sau altă tensiune de comandă necesară panoului. |
Machinae FerramentariaeMașinile-unelte folosesc frecvent contactori, frâne electromagnetice și supape electromagnetice care generează un curent momentan ridicat în momentul pornirii. Un transformator de control corect ales ajută la menținerea unei tensiuni de comandă suficiente în mașinile cu comandă numerică (CNC), mașinile de tăiat, presele, mașinile de ambalat și alte echipamente de producție. |
Instrumenta automation industriaeSystemata automationis transformatoribus regulandi utuntur ad auxiliare potestatem AC pro interface PLC, relectoribus, actuatoribus, sensoribus et circuitibus regulandi supplicandam. Plures secundariae avoluciones designari possunt cum diversa instrumenta regulandi circuitus voltaticos separatos aut isolationem electricam requirunt. |
Systemata HVAC et RefrigerationTransformatores regulandi in frigoriferiis, systematibus refrigerationis, instrumentis tractationis aeris et systematibus HVAC commercialibus utuntur. Potestatem regulandi ad contactores, valves, relectores, circuitus thermostaticos et alia instrumenta auxiliare supplicare possunt. Designatio temperaturam armarii, ventilationem et frequentiam commutationis considerare debet. |
Ascensores, Scalae Mobiles et Portae AutomaticaeInstrumenta levationis et controlus accessus transformatoribus regulandi uti possunt ad relectores, frenos magneticos, circuitus regulandi portarum et alia componentia auxiliare alimentanda. Bracchia montagii specialia et dispositiones terminalium pro installatione intra armarios electricos compactos disponibilia sunt. |
Pompa et Instrumenta Tractationis AquaeControl transformers can provide control power for motor starters, level-control relays, solenoid valves, and monitoring circuits in pump stations, water-treatment equipment, and industrial process systems. For outdoor or humid installations, the transformer should be installed inside a suitable protective enclosure. |
Cur ECKO eligere?
More Than a Transformer Supplier: Engineering Support for OEM Control Systems
1. Load Analysis Before Transformer SelectionWe do not select a control transformer only according to continuous watts. Our engineering review can include the continuous VA, inrush VA, sealed VA, switching sequence, duty cycle, and minimum pickup voltage of the connected contactors, relays, solenoids, or brakes. This helps reduce the risk of an undersized transformer, excessive voltage drop, or unnecessary oversizing. |
2. Electrical and Mechanical Design Reviewed TogetherA transformer must provide the required output performance and fit correctly inside the customer’s cabinet. ECKO recenset tensionem, currentem, regulatio, incrementum temperaturae, insulationem, accessibilitatem terminalium, distantiam foraminum ad montandum et spatium totale ad installandum ut partem eiusdem processus designandi. |
3. Translatio Controlata a Exemplari ad ProductionemDescriptio producti approbata, informationes de avolutione, requisita materialia, mappa terminalium, contentum tituli et criteria inspectionis fiunt referentia productionis. Haec translatio controlata sustinet consistentiam inter exemplaria approbata et ordines futurae productionis. |
4. Requisitiones Conformitatis Consideratae PrimoRequisitiones certificationis pendunt ex exacto modello transformatoris, materialibus insulationis, apparatu finali et mercato destinato. ECKO recenset requisita documentorum CE, CQC, RoHS aut aliorum in stadio citationis et designi, non ut affirmationes genericae fabricae. |
5. Communicatio Ingenierii pro Projectis Ad HocClientes accipiunt specificatio clare definita et descriptio ad approbandum. Technical changes involving voltage, winding material, terminals, mounting, or protection are documented to avoid misunderstandings among purchasing, engineering, and production teams. |
6. Experienced Transformer ManufacturingEcko Electrotech has manufactured customized transformers and wound components since 2000. Our manufacturing resources include three workshops covering approximately 5,000 square metres, supported by experienced production and quality-control personnel. Our producta are supplied to customers in more than 30 countries and regions. |
Qualis Testis
Electrical Safety and Performance Verification
ECKO combines incoming-material inspection, in-process control, routine electrical testing, and design-validation testing.
The exact test items, limits, sampling level, and test conditions are confirmed according to the approved product specification.
| Test Item | Quod Verificat | Gradus Controllii |
| Inspectio visualis | Workmanship, core assembly, terminals, label, and surface condition | Inspectio Ordinaria |
| Inspectio Dimensionum | Overall size, mounting-hole spacing, and terminal position | Inspectio Ordinaria |
| Continuitas avolucrum | Connexiones Electricae Rectae et Completae | Examen Ordinarium |
| Ratio Spirearum et Polarity | Ratio Tensionis Recta et Relatio Terminalis | Examen Ordinarium |
| Tensio Exiens Sine Onere | Tensio Secundaria Antequam Onus Coniungitur | Examen Ordinarium |
| Currus sine onere | Condicio Magnetica et Performantia Nuclei | Examen Ordinarium |
| Resistens Insulationis | Integritas Isolationis Inter Vindicationes et Partes Metallicas Accessibiles | Examen Ordinarium |
| Resistentia Dielectrica / Hi-Pot | Insulatio resistens ad tensionem specificatam in experimento | Examen Ordinarium |
| Tensio exirens sub onere nominato | Praestatio tensionis sub onere continuo specificato | Design validation |
| Voltage Regula | Differentia inter tensionem exirentem sine onere et tensionem exirentem sub onere nominato | Design validation |
| Simulatio influxus/activationis | Tensio secundaria dum onus commutativum definitur | Quod erat faciendum |
| Probatio incrementi temperaturae | Praestatio thermica sub onere convento et condicionibus ambientibus | Design validation |
| Examinatio soni et vibrationis | Fixatio nuclei, impregnatio et coniunctio mechanica | Sicut specificatum |
| Examen finalis del etiqueta | Modello correcte, valorationes, marcas del terminal e information del lotto | Inspectio Ordinaria |
Processus de controllo de qualitate:
Notula Importans:
Ascensus temperaturae et regulatio output dependet ex designo transformatoris, facto potentiae oneris, positione installationis, temperatura armarii et ventilatione. Da, quaeso, ambientes operationis expectatos ut conditiones validationis rectae constituere possimus.
Processus Adaptandi
A Requisitionibus Technicis ad Productionem Regulatam
Gradus 1: Collectio RequisitionumCliens praebet: |
Gradus 2: Aestimatio IngenieriaECKO evaluat magnetikum kernum, vinculum structuram, conductoris magnitudinem, tensionis regulatum, temperaturae incrementum, insulationis systema, terminalium dispositionem et montagii constructionem. Si inrush VA non disponibilis est, cliens potest praebere contactoris, rellais, freni aut solenoide datasheet pro examini. |
Gradus 3: Quotatio et Propositio TechnicaNos praebemus commercialem quotatiōnem una cum proposita electrica et mechanica configuratione. Quaelibet speciales exigentiae quae involvunt cuprum vinculum, protectionem thermicam, scutum aut documenta conformitatis hic confirmari debent. |
Gradus 4: Descriptiōnis ApprobātiōCliens recenset et approbat: Productio exemplaris incipit postquam descriptiō technica et specificatio sunt approbatae. |
Gradus 5: Productio Exemplaris et ExaminatioExemplaria secundum approbatos documenta technica fabricantur. Functiones electricae, insulatio, dimensiones et articuli validationis specificati ante expeditionem examinantur. |
Gradus 6: Verificatio Apparatus a ClienteCliens exemplar in apparatus destinatus installat et verificat: |
Gradus 7: Productio MassivaPost approbationem exemplaris, descriptio confirmata, elenchus materialium, processus productivus et criteria inspectionis ad productionem massivam transferuntur. Inspectiones rutinales et ultima confectionis operatio secundum approbatas ordinis conditiones perficiuntur. |
Quaestiones frequenter factae de transformatoribus BK de controllo
1. Quid significat "BK" in transformatore BK de controllo?
BK est series designationis communiter usitatae pro transformatoribus de machina et de controllo industriali. Designatio BK sola non definit tensionem input, tensionem output, valorem VA, classem insulationis aut certificationem. Haec parametra confirmanda sunt in specificatio producti.
2. Quae est differentia inter transformatorem de controllo et standardem power Transformer ?
Transformator de controllo communiter utitur ad supplendum contactores, relays, solenoides, frenos electromagneticos et alia dispositiva commutandi.
Haec onera possunt trahere currentem momentaneam altam durante tempore accipiendi. Ergo transformator de controllo seligitur secundum onus continuum et exigentiam inrusionis brevi duratione, non solum secundum potentiam operationis normalis.
3. Quomodo calculare valorem VA necessarium?
Praebere va inrumpentem et va obsignatum uniuscuiusque dispositivi connecti, una cum ordine commutandi.
Si plura dispositiva simul excitari possunt, eorum necessitas inrumpens simul consideranda est. Dispositiva quae manent excitata ad onus continuum contribuunt.
ECKO auxilium praebere potest in calculo post examen datum oneris.
4. Cur va inrumpens importante est?
Contactor aut solenoide saepe multoties correntem suam obsignatam in prima parte operationis trahit.
Si transformator parvus est nimis, voltatio secundaria sub voltationem minimam accipiendam dispositivi cadere potest. Hoc chattering, operationem incompletam, calefactionem nimiam aut perficiendum machinae incertum causare potest.
5. Cur transformator 24 V interdum plus quam 24 V sine onere mensurare potest?
Transformator normaliter altiorem voltationem secundariam habet sub condicionibus sine onere. Voltatio diminuitur cum onus nominatum connectitur propter resistentiam spire et impedantiam internam.
Voltages acceptabiles sine onere et plene oneratae secundum tolerantiam oneris definire debent.
6. Num transformator controlis AC 380 V, 400 V aut 415 V ad 24 V fabricari potest?
ECKO transformatores cum ingressu 380 V, 400 V aut 415 V et egressu 24 V AC ad mensuram conficere potest.
Aliae voltages ingressus et egressus etiam habiles sunt. Frequenticam, currentem egressus postulatum, onus continuum et VA impulsum indicare placet.
7. Num unus transformator plures derivationes tensionis ingressus continere potest?
Plures derivationes in primario convolutu pro diversis tensionibus retis, ut 380 V, 400 V et 415 V, designari possunt.
Derivationes postulatae, dispositio terminalium et isolatio derivationum non usitarum in tempore conceptionis confirmandae sunt.
8. Num transformator plus quam unam tensionem egressus praebere potest?
Plures secundarios convolutos independentes, egressus cum medius punctus, aut plures tensiones egressus designare possumus.
Tensionem et currentem ex singulis convolutis postulatas, necnon an egressus inter se electrico isolati esse debeant, specificare placet.
9. Num duo secundariae avolucres parallele coniungi possunt?
Solum secundariae avolucres, quae speciatim ad eandem tensionem, impedantiam et polaritatem designatae sunt, parallele coniungi possunt.
Ne duae separatae avolucres exiens sine scripta confirmatione parallele coniungantur, quia currentes circulatoriae et inaequalis onus distributio fieri possunt.
10. Num transformator regulans tam ad 50 Hz quam ad 60 Hz operari potest?
Si speciatim ad operationem 50/60 Hz designatus est et ita notatus.
Transformator, qui solum ad 60 Hz designatus est, non debet automatio ad 50 Hz sub eadem tensione intrantis uti. Operatio ad minorem frequentiam fluxum magneticum, currentem sine onere, sonum audibilem et incrementum temperaturae augere potest.