Omnes Categoriae

Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Telephōnum mōbile
Nomen
Nōmen societātis
Notula
0/1000

Transformatores Aquae Resistentes

Pagina Prima >  Producta >  Transformatores Impermeabiles

Custom Low Voltage Landscape Lighting Transformer for Outdoor Use

Designed for garden, lawn, courtyard and architectural lighting systems, with custom input voltage, multiple outputs, thermal protection and outdoor-rated cable options.

  • Conspectus
  • Producta Commendata
Specifikationes Transformatoris Externae Tensionis Infimae
Parameter Optiones Disponibiles
Product Type Encapsulated isolation, step-down or step-up transformer
Typical Rated Power 30VA–200VA; gradus superiores secundum applicationem examinandi
Voltage input 100V, 110V, 120V, 220V, 230V, 240V, 380V, 400V, 415V AC or custom
Output Voltage 6V, 9V, 12V, 18V, 24V, 36V, 48V, 60V, 72V, 110V AC or custom
Frequency 50Hz / 60Hz
Phasis Singula Phasium
Protectio IP IP65 or IP67; special immersion requirements evaluated separately
Materia curva Copper winding with wire grade selected for the design
Encapsulatio Resina epoxida conductora termicamente
Insulatio Classis Classis B, F aut H secundum requisita temperaturae
Isolatio Electrica Isolatio primaria ad secundariam secundum designatum approbatum
Protectio Interna Fusibilis thermalis, protector thermalis reponibilis aut optiones fusibilis
Theca Habitaculum rotundum, quadratum, metallicum, plasticum aut speciale pro projecto
Optiones Cabilorum Longitudo, color, vestimentum, terminales, connexiones et connexiones impermearum ad mensuram
Montatio Foramina ad fixandum, brachia, fixatio centralis aut basis ad mensuram
Ambiens Operativum Definitum secundum temperaturam ambientem, umiditatem, chemicas et modum installationis
Supportus pro conformitate CE, RoHS, CQC secundum modellos et requisita proiecti
Sample plumbum Tempus Tam cito quam 1–3 dies, ubi materiae idoneae adstant

Omnes specificatones in descripto approbato definitae sunt. Gradus protectionis IP ad totam compositionem finitam sub condicionibus testis et installationis conventis applicatur.

11f298ecd5aef7ee62b2542740d7ec30.jpeg
Formam
A
B
C
D
E
F
Potentia
EKE-EI66
94.0
63.0
69.0
83.0
48.0
4.3
40-60W
EKE-EI86
129.0
85.0
83.5
112.0
66.0
6.3
100-150W
EKE-EI86
151.0
93.5
98.0
131.0
66.5
6.3
200-250W
EKE-EI114
164.0
110.0
151.0
142.0
76.0
6.3
300-400W
EKE-EI133
230.0
153.0
140.0
198.0
115.0
6.3
500-600W
*Parametrum tantum ad referentiam pro datis typicis, alia autem secundum mandatum suscipimus.
*Nos possumus praebere tibi transformatorum quadratum aquae resistentem 20VA ad 600VA.

Sex rationes cur ingeniarii transformatorum aquarum impervium ad mensuram praescribant

Completa encapsulatio epoxy

Epoxy thermice conductivum involvit internum torquem et conglobationem nucleorum, ut componentes critici protegantur ab umore, pulvere et vibratione. Systema resinis et processus indurationis secundum augmentum temperaturae et ambientem operationis eliguntur.

Isolatio electrica pro instrumentis voltaminis infimi

Volvulae primariae et secundariae separatae isolationem galvanicam inter suppetias principales et instrumenta voltaminis infimi praebent. Spissitudo insulationis, distantia percurrendi et fortitudo dielectrica secundum designatum certificatum tutelae definitur.

Voltaminis constantia sub onere reali

Magnitudo nucleorum, numerus volvularum et diametrum fili copri secundum onus reale, cyclum operis, longitudinem cavi et regulam voltaminis requisitam calculantur. Haec ad minuendam voltaminis exirentis inopinatam depressionem et operationem instabilem instrumentorum confert.

Designum controllo augmenti temperaturae

Spiralis, nucleus magneticus, vasum et materia impregnans ut unum systema thermicum considerantur. Confirmatio incrementi temperaturae sub condicionibus oneris et ambientis conventis ante productionem massam fieri potest.

Optiones Cabilorum et Conectorum Externa

Longitudo cabilorum, materia tegumenti, color filorum, glandula aquae-resistens, dispositio contra tensionem, connexio et conector ad instrumenta clientis adaptari possunt. Exitus cabilorum ita designati sunt ut stressum trahendi et ingressum humidi minuant.

Designatio Mechanica Specifica Applicationi

Habitationes rotundae et quadratae, foramina ad fixandum, directio exitus cabilorum, dimensiones generales et notae ad usum personalizari possunt. ECKO etiam modulos substitutionis ex schemate, specificatio aut exemplari physico iam existente elaborare potest.

Optiones Personalizandi

Transformatores Aquae-Resistentes Personalizati Secundum Instrumenta Vestra

Un transformator impermeabilis debet designari non solum pro voltatibus intrantis et extrantis. ECKO aestimat onus electricum, modum installationis, condiciones ambientales, distantiam cavi et protectionem securitatis necessariam antequam designum definit.

Categoria Variabilis Optiones Disponibiles
Voltage input Unum intritum, duplex intritum, multae derivationes aut selector voltatus
Output Voltage Unum extritum, duplex extritum, multae volutationes independens aut punctum medium
Potentia Aestimata Adaptatum secundum onus continuum, currentem initiationis et cyclum operationis
Frequency 50Hz, 60Hz aut 50/60Hz
Protectio IP IP65, IP67 aut protectio ambientalis definita a projectu
Habitationem Rotundum, quadratum, plasticum, metallicum aut custos speciale ab cliente
Materies implantationis Formula epoxidica electa secundum transductionem caloris et ambientem
Systema Isolationis Classis B, F aut H; insulatio fortificata ubi requiritur
Componentes protectionis Fusibilis thermalis, protector restituibilis, fusibilis primarius aut fusibilis secundarius
Cable Conventus Longitudo cavi personalisata, color, calibro, connector, terminalis et connexio
Montatio Placa basalis, foramina montantis, brachia aut montatio centralis
Exsecutio Regulatio tensionis, augmentum temperaturae, currentis sine onere et optimisatio impetus
Identificatio Emblema clientis, tabella gradus, numerus serialis et confectio privata
Documenta Figurae, diagramma connexionum, requisita inspectionis et scheda data technica

Informationes requiruntur ad citationem personalisatam

  • Tensio et frequencia intrantis
  • Tensio exiens requisita
  • Currentis exiens nominis aut VA
  • Genus oneris et currentis initiationis
  • Officium continuativum aut intermissivum
  • Ambiens Temperature
  • IP rating obligatorius
  • Longitudo cavi et typus connexoris
  • Dimensiones maximae et modus montandi
  • Patria destinata, norma securitatis et quantitas annua

Ubi transformatoribus aqua-resistentibus utitur?

Systemata illuminationis piscinarum

Transformator isolans ad tensionem bassam (12 V vel 24 V AC), ad usum specialem, potest praebere lucernas piscinae ad tensionem bassam ex ingressu retis electrici (110 V, 120 V, 220 V, 230 V aut 240 V). Transformator in loco secundum codices et regulas electricas locales extra piscinam installandus est.

Illuminatio agri et horti

Transformatores aqua-resistens praebent potestatem ad tensionem bassam pro lucernis horti, lucernis viarum, lucernis focalibus et aliis systematis illuminationis agri, quae pluviae et humidi exposuntur. Tensio egressus ad longitudo cavi et cadere tensionis expectatum regula potest.

Fontes et ornatus aquosi

Fons lucis, systemata nebulae et ornata aquae elementa saepe exigunt isolatum energiam ad voltum parvum prope humidam regionem operativam. Capsa, resina inculcata, exitus cavi et modus adfixionis seliguntur secundum conditiones installationis.

Exterioris Architecturae Illuminatio

Transformator ad usus speciales aptari potest pro illuminatione faciarum, signorum, cortilium et commercialis exterioris illuminationis. Plures circuitus output vel plures circuitus luminis considerari possunt in statu designandi.

Thermae et Intelligens Apparatus Balneorum

Transformator impervius aquae potest praebere luminaria ad voltum parvum, circuitus de controllo et apparatus electricos auxiliares in systematibus thermarum et balneorum. Regio installationis, requisita de insulatione et normae securitatis applicabiles confirmandae sunt antequam productio incipiat.

Apparatus Marini, Irrigationis et Aquarum Sordidarum

Specialis dispositions transformerum aqua-resistentium pro machinis auxiliaribus maritimis, systematibus irrigationis et systematibus sordium aquarum possunt aestimari. Sal, chlorum, chymica, radiatio UV et exigentiae de corrosione specificandae sunt in recensione technica.

Cur emptores OEM ECKO eligerunt pro projectis transformerum aqua-resistentium

Ingenium ad applicationem

Nos recensimus genus oneris, cyclum operis, distantiam cable, temperaturam ambientem, zonam installationis et requisita tutelae ante definitivam electionem transformeris. Haec adiuvat ut vitetur electio VA incorrecta, augmentum temperaturae excesivum et instabilis tensio exiens.

Dispositio electrica et mechanica in uno projecto

Volvulae transformeris, nucleus magneticus, capsula, resina, glandula cable et structura fixationis simul elaborantur ut una composita perfecta. Hoc praesertim necessarium est cum protectio IP et performantia thermica simul obtineri debent.

Documentatio dispositionis regulata

Input, output, wire size, protection components, dimensions, cable pinout, and label information are recorded in the approved drawing. Engineering changes can therefore be reviewed and controlled before they enter production.

Waterproofing Beyond an Outer Coating

A reliable waterproof design depends on the resin, housing, cable jacket, cable entry, strain relief, curing process, and installation method. ECKO evaluates these details instead of relying only on an external waterproof label.

Prototype and Production Capability

Established in 2000, ECKO operates three workshops covering approximately 5,000 square metres with 150 skilled workers and annual capacity of around one million wound-component products. Prototype lead time can be as fast as 1–3 days when the required materials are available.

Technical Support from Sample to Mass Production

Clientes possunt confirmare praestantiam electricam, dimensiones, conformationem cataractarum, titulos et aptitudinem ad installationem per exemplar ante productionem. Requirimenta inspectionis et relationes examinum specificae pro projecto conveniri possunt durante approbatione exemplarium.

Qualis Testis

Inspectio et validatio transformatoris aqua-resistentis

Examina electrica routine et examina validationis designi diversa proposita habent. Limites finales examinum et frequentia inspectionis in specificatio approbata vel in plano controlis annotari debent.

Test Item Scopus Frequentia Recommandata
Inspectio visualis et dimensionalis Confirmat corpus, titulum, catenam, fixationem et artificium 100%
Continuitas avolucrum Detegit circuitus apertos et coniunctiones incorrectas 100%
Ratio conversionis / Tensio sine onere Confirmat rationem tensionis inter input et output 100%
Currus sine onere Examinat consistentiam designi magnetici et confectionis Examinatio routine aut sampling consensum
Resistentia circumvolutionis Verificat consistentiam avolutionum et statum conductoris Examinatio routine aut sampling consensum
HI-POT TEST Verificat isolatio electrica inter spira et partes accessibiles 100% cum in planum controlus approbatum includitur
Resistens Insulationis Examinat statum insulationis et percolationem ex umore Examinatio routine aut sampling consensum
Continuitas terrae Confirmat connexionem terrae protectricem in casus metallicos applicabiles 100% ubi applicabile
Examen tensionis sub onere Confirmat tensionem exire sub onere specificato Verificatio per exemplar et per lotum
Probatio incrementi temperaturae Validat performance thermicam ad onus nominale et ad conditionem ambientem Validatio designis aut probatio typi
Probatio protectoris thermalis Confirmat protectoris electi et requisitorum disiunctionis Verificatio componentium et exemplarium
Probatio IP / ingressus aquae Confirmat integrum designum incapsulantis et introitus cavi Probatio typi aut examinatio proiectu definita
Inspectio potting et indurationis Examinat implens resinis, conditionem superficiei et consistentiam indurationis Inspectio visualis cum controllo partuum
Finalis Functionalis Testus Confirmat correctam connexionem, polaritatem et operativam performancem 100% aut convenit Planum Controlis

Declaratio Qualitatis:

Omnis expeditio sequitur approbatam specificationem producti. Registra testuum, relationes inspectionis aut data validationis specifica pro projecto possunt discuti in tempore citationis et approbationis exemplaris.

Ab Requisitis Applicationis ad Transformatorum Waterproof Paratum ad Productionem

Gradus 1 — Examinatio Applicationis

Mitte tensionem input, tensionem output, currentem nominalem, typum oneris, distantiam cavi, temperaturam ambientem, requisitum IP et informationem installationis.

Gradus 2 — Examinatio Ingenieriae

ECKO examinat capacitatem transformatoris, designum avolutionum, regulatum tensionis, incrementum temperaturae, insulationem, componentes protectionis, involucrum et confectionem cavi.

Gradus 3 — Quotatio et Schema

Tu accipis quotatio commerciale una cum propositione specificationum electricarum et mechanicarum. Parametri principales confirmantur ante productionem prototypi.

Gradus 4 — Fabricatio Prototypi

Exemplar ad usum specialem fabricatur ex materialibus et constructione consensu acceptis. Tempus ad exemplar praeparandum potest esse tantum 1–3 dies pro iis projectis idoneis quibus materiae iam habentur.

Gradus 5 — Verificatio Exemplaris

Cliens examinat functiones electricas, dimensiones, modum fixationis, conexiones cabilorum et operationem cum instrumento vero. Omnes mutationes necessariae recensentur antequam approbatio datur.

Gradus 6 — Exercitatio Initialis et Productio Massiva

Postquam exemplar est approbatum, productio sequitur schemata, materiales et requisita inspectionis iam confirmata. Quantitas initialis exercitii disponi potest si validatio additiva requiritur.

Gradus 7 — Inspectio Finalis et Distrubutio

Perfectus producta inspiciuntur et implicantur secundum specificatum conventum. Cartones, palletae, impacationes cum nomine proprio et documenta exportationis ad voluntatem adaptari possunt.

FAQ Transformatoris Externae Resistentis ad Humiditatem

1. Num transformator resistens ad aquam necessario territur?

Requirimenta territionis dependent a constructione isolationis, materia cistae, classe protectionis et regulis electricis localibus. Cista metallica aut pars montionis conductiva exposita fortasse requirit territionem protectivam, dum designatio duplex-isolata alium modum protectionis uti potest.

2. Ubi fusibiles aut interruptores circuitus insallandi sunt?

Protectio forte requiritur in parte primaria, parte secundaria, vel utraque, secundum designatum transformatoris et onus coniunctum. Apparatus protectivus seligi debet secundum currentem nominalem, currentem initiationis, capacitatem cavi, et requisita securitatis applicabilia.

3. Quid accidit, cum protectio thermalis transformatoris activatur?

Exsuscitatio transformatoris interrumpi potest, si temperatura interna superat limitem protectionis. Protector thermalis automaticus post refredationem saepe se ipse restituit; fusibilis thermalis autem saepe non restituitur. Typus protectionis electus debet cum strategia securitatis requirita congruere.

4. Num transformator plene impotus aquae-resistantis reparari potest?

Transformator plene inclusus saepe non ad reparandum internum destinatur, quia spira et componentes protectivi in resina includuntur. Si unitas impota deficiat, substitutio saepe tutior et utilior est quam conatus apertionis eius.

5. Num transformator resistere potest chlоро, fertilizantibus aut substantiis purgativis?

Protectio aquae-resistens communis non garantit resistentiam ad omnem substantiam chemicam. Pro ambientibus piscinarum, hortorum aut agricolarum, custodia, tunica cavi, sigilla et apparatus fixationis secundum expositionem chemicam expectatam eligendi sunt.

6. Num transformator includit protectionem contra fulgura et fluctuationes?

Insulationis basicae transformatoris non praebet protectionem perfectam contra fulgura graviora aut fluctuationes in rete electrico. Fortasse dispositiva externa pro protectione contra fluctuationes requiruntur, praesertim pro longis circuitibus exterioribus et in locis ubi fulgura frequenter accidunt.

7. Num transformator ab generatori vel inversore operari potest?

Fortasse possibile est, sed generator vel inversor debet praebere voltatgem, frequentiam et formam undae correctas. Qualitas inferior formae undae, spiculae voltatis aut frequentia instabilis sonum transformatoris, incrementum temperaturae et currentem sine onere augere possunt.

8. Quomodo ECKO consistentiam inter exemplaria et productionem massivam regit?

Descripta approbata, tabulae materiarum, specificationes avolutionum et instructiones processus ante productionem reguntur. Parametri critici, ut ratio avolutionum, magnitudo fili, materia nuclei, structura insulationis et limites experimentorum, notantur ut consistentia per partus servetur.

9. Quales documenta ECKO praebere potest pro projecto transformatoris impermeabilis OEM?

Secundum projectum, ECKO praebere potest schemata productorum, diagrammata connexionum, specificata, informationem de materiis, relationes examinum exemplarium et acta inspectionum. Supportus certificationis et validatio additiva secundum mercatum destinatum et postulationes ordinis tractari possunt.

Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Telephōnum mōbile
Nomen
Nōmen societātis
Notula
0/1000
  • Turma R&D

    Turma R&D

    Fortis facultas designandi et evolvendi, nostra cohors R&D, plus quam 20 annos experientiae in industria, solutiones completas praebemus. Facimus exemplaria celeriter, celerrime die uno.

  • Tempus Traditionis

    Tempus Traditionis

    Nostra flexibilis productio et periti operarii, exemplar confici potest in 1-3 diebus, ordo infra 10000pcs tradier possit in 10-20 diebus, negotiabile secundum casus.

  • Qualitas

    Qualitas

    inspectio et examinatio 100% ante traditionem, producta certificationes CE/ROHS/CUL obtinuerunt, praestatur qualitas biennalis.

  • xXIV Horae Online Service

    xXIV Horae Online Service

    Clientes globales, nullum tempus obstaculum. Celeriter iuvamus in ordinibus, productione, technicis et quaestionibus. Continge nos aut visita fabricam nostram.

Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Telephōnum mōbile
Nomen
Nōmen societātis
Notula
0/1000

Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Telephōnum mōbile
Nomen
Nōmen societātis
Notula
0/1000

Petite Quotationem Gratis

Noster legatus te cito adibit.
Electronicum
Telephōnum mōbile
Nomen
Nōmen societātis
Notula
0/1000