Application-Matched Copper Windings
Wire gauge and turns are calculated for the required current, voltage regulation and temperature rise. Single, split and multiple secondary windings can be integrated into one transformer.
Transformatoris EI laminati ad usum conversionis stabilis tensionis AC et isolationis electricae, facti ad mensuram. Indicate tensionem input et output, valorem VA, modum fixationis, classem insulationis, terminations, scutum et protectionem quas apparatus vester requirit.
ECKO designat et fabricat transformatoris monofasicos cum nucleo EI secundum onerem realem, incrementum temperaturae praefinitum, spatium installationis disponibile et requisita securitatis applicabilia. Omnis modelus ad mensuram emittitur secundum schemata et specificata electrica approbata ante productionem in serie.
The table below describes ECKO's configurable EI transformer platform. Final values are defined by the approved model drawing and test specification.
| Product Type | Single-phase, low-frequency laminated EI core power Transformer |
|---|---|
| Potentia Aestimata | Custom VA rating based on load, duty cycle, core size, allowable temperature rise and enclosure conditions |
| Voltage input | Custom single-voltage, dual-voltage or multi-tap primary; common ranges include 100–120 VAC, 200–240 VAC and industrial mains voltages |
| Output Voltage | Custom low-voltage AC output; single, dual, multiple isolated or centre-tapped secondary windings available |
| Frequency | 50 Hz, 60 Hz or 50/60 Hz, as specified |
| Core and winding | Low-loss silicon steel EI laminations with enamelled copper wire windings |
| Configuratio Electrica | Isolation, step-down or step-up design; autotransformer configuration available when galvanic isolation is not required |
| Systema Isolationis | Classis B, F aut H optiones secundum designum thermicum et requisita applicabilia |
| Voltage Regula | Specificata ad inputum nominalem, onus et factorem potentiae; optimizata pro applicatione obiectiva |
| Optiones Montandi | Pinus PCB, fili conductores, taggulae soldaturae, blocchi terminalium, bracchia, pedes montantes, cingula aut hardware ad usum specialem |
| Optiones Protectionis | Fusibilis thermalis, protector thermalis restituibilis, provisio fusibilis externi et alia protectiones specifica pro projecto |
| Optiones pro strepitu et scuto | Impregnatio vernicis, scutum electrostaticum, scutum magneticum aut attenuatio mechanica ubi opportuna technice |
| Documenta | Descriptio formae, diagramma connexorum, specificatio electrica et acta inspectionis specifica pro projecto disponibilia |
| Supportus pro conformitate | Supportus pro designo CE, UL/cUL, CQC et RoHS disponibilis; status certificandi et notatio confirmari debent pro modello exacto |
Wire gauge and turns are calculated for the required current, voltage regulation and temperature rise. Single, split and multiple secondary windings can be integrated into one transformer.
The EI lamination stack, flux density and winding design are selected as one thermal system. This helps control no-load loss, loaded voltage and operating temperature.
Bobbin geometry, interlayer insulation, margin tape and lead routing are defined around the required working voltage, dielectric strength and insulation class.
Core clamping, controlled assembly and optional varnish impregnation help limit lamination vibration. Noise targets can be evaluated for audio, office and indoor equipment.
Elige pinos de PCB, conductores, terminales, conectores, soportes o un bastidor personalizado. ECKO puede trabajar a partir de tu envolvente disponible, diseño de PCB o una muestra existente de transformador.
Los planos aprobados, los datos de devanado y los límites de prueba se convierten en la base de producción. Las comprobaciones eléctricas rutinarias ayudan a mantener de forma constante la polaridad, la relación de tensión, la corriente en vacío y el rendimiento del aislamiento.
Un transformador debe diseñarse en torno al equipo, no seleccionarse únicamente por su tensión. ECKO evalúa conjuntamente los requisitos eléctricos, térmicos, mecánicos y de conformidad.
Rango de entrada, derivaciones primarias, tensión y corriente de salida, potencia aparente (VA), frecuencia, ciclo de trabajo, regulación y corriente en vacío.
Secundarios simples, dobles, con toma central o múltiples; salidas aisladas; conexión en serie/paralelo y polaridad definida por el cliente.
Tamaño del núcleo EI, dimensiones globales, centros de montaje, huella de PCB, soportes, bastidores, cubiertas y orientación de instalación.
Longitudo et color fili ducens, tegumentum, lamellae Faston, tabellae soldaturae, pinnulae pro tabula circuituum impressorum, blocchi terminalium et conectora specificata.
Classis isolationis, requisita dielectrica, distantiis de percolatione et de separatione, fusibilis thermalis, protector thermalis et protectio environmentalis specifica pro projecto.
Scutum electrostaticum, scutum fluxus, impregnatio et attenuatio mechanica, electa tantum cum ab ratione systematis postulantur.
Mitte informationes sequentes. Si quaedam valorum ignota sunt, aequipe ingeniaria ECKO eos definire potest ex onere apparatus et conditionibus operationis.
EI laminatus transformatores latissime utuntur ubi isolatio frequentialis retinenda, conversio voltatis, plures exirentes et adfixio flexibilis magis important quam minimum magnitudo. Designatio finalis ad onus et ambientes operationis accomodanda est.
Circuits de alimentation pro regulandis circuitibus, relectoribus, contactoribus, interfaciis PLC, sensoribus et oneribus auxiliaribus intra machinas vel arcae de controlu. Primariae multi-tap possunt sustinere instrumenta vendita in pluribus mercatis tensionis principalis.
Praebent railes AC isolatos pro alimentationibus amplificatorum, praeamplificatorum et processuum signorum. Densitas fluxus, impregnatio, scutum et adfixio optimizari possunt ad sonum auditibilem et copulationem magneticam regendam.
Metra potencie, instrumenta laboratorii, tabulae de controllo, et circuitus auxiliarii isolati. Avoluciones secundariae separatae possunt sustinere sectiones analogicas, digitalis, et de relectoribus ex uno componente magnetico.
Gradat voltationem principalem ad thermostatia, tabulas de controllo, valvulas, relectores, et contactores. Designatio thermica debet rationem habere temperaturae armarii, ventilationis, et postulationis intermittendae onerum inductivorum.
Suppeditat controles luminis ad voltationem inferiorem, signa, ostensiones, et apparatus architectonicos. Transformator potest designari pro profilo oneris, carchassio, et modo installationis requisitis.
Uti in machinis vendentibus, apparatus pro caffeo, apparatus pro massagio, apparatus parvi, et aliis producta qui requirunt AC ad voltationem inferiorem et isolatam. Conformitas et protectio seliguntur pro apparatu perfecto.
ECKO pot comparare constructiones EI, toroidales, R-core, montatas in PCB aut inclusas ad tuos limites pro pretio, magnitudine, fuga magnetica, currente initiale, fixatione et volumine productionis.
mitte requisita tua de instrumentis pro recommendatione technica.
ECKO coniungit ingenium transformatorum, customizationem regulatam et productionem amplificabilem. Finis non est tantum transformatoris suppeditatio, sed liberatio componentis repetibilis quae conveniat instrumentis emptoris, documentis et processu approbationis.
Testing is performed against the approved model specification. Routine tests verify production consistency, while design-validation tests confirm performance under the agreed operating conditions.
| Inspection or test | Quod Verificat | Typical stage |
|---|---|---|
| Ingressus Materialis Inspectio | Core laminations, wire specification, bobbin, insulation, leads and key purchased components | Imperium Qualitatis Intrantis |
| Winding and polarity inspection | Turns, wire gauge, winding sequence, taps, polarity and interlayer insulation | In process |
| Continuity and DC resistance | Correct connections, conductor integrity and winding-to-winding consistency | In process / final |
| Turns ratio and no-load voltage | Primary-to-secondary ratio, output tolerance and correct tap identification | 100% routine test |
| No-load current and no-load loss | Core assembly, excitation behaviour and abnormal winding or lamination conditions | Routine or sampling, as specified |
| Load and voltage-regulation test | Rated output, loaded voltage, current capability and regulation | Design validation / sampling |
| Resistens Insulationis | Integrity of the insulation system between windings and core or accessible metal parts | Routine, as specified |
| Dielectric withstand (Hi-Pot) | Integritas isolatio ad tensionem et tempus probationis conventos | probatio securitatis rutinaria 100% ad limites approbatos |
| Probatio incrementi temperaturae | Praestatio thermalis ad condiciones specificatas de input, oneris, ambientis et installationis | Validatio prototypi / typi |
| Dimensiones et artificium | Magnitudo exterior, centra montandi, longitudo conductorum, etiquettae, terminalia, impregnatio et coniunctio | In process / final |
Importans: Exactae tensiones probationis, limites acceptationis, gradus exemplorum et relationes requiruntur ut confirmarentur in plano qualitatis approbato. Approbatio securitatis pro uno modello transformatoris EI non automatico extenditur ad omnes variantes ad usum specialem.
Processus approbationis documentatus minuit errores technicos et certificat quod aequipes emptionis, ingeniorum et qualitatis eandem specificationem transformatoris examinent.
Provide electrical load, mains input, dimensions, mounting, environment, compliance and quantity information.
ECKO reviews core size, windings, thermal margin, insulation, mechanical construction and test requirements.
You receive a commercial quotation together with the key technical assumptions or an outline specification.
Samples are manufactured for electrical, mechanical and equipment-level evaluation. Qualified designs may be accelerated subject to material availability.
Both parties confirm voltage, regulation, temperature, noise, mounting, leads, labels and other agreed characteristics.
The final drawing, wiring diagram, materials, test limits and change controls are approved before production.
Production follows controlled winding data and inspection criteria, with first-batch review when required.
Finished transformers are tested, packed to the agreed method and supported with shipment documents and after-sales response.
These answers address common engineering and purchasing questions for custom EI transformers. Final performance is always governed by the approved specification for the exact model.
Start with the continuous apparent power of every secondary: voltage multiplied by RMS current. Add the outputs, then account for rectifier type, capacitor-input current peaks, motor or relay starting current, duty cycle, ambient temperature, enclosure ventilation and the required regulation. ECKO can calculate the design VA when you provide the real load circuit or measured current waveform.
Resistentia et impedantia fuga inductorum causant cadere tensionem dum correns crescit. Transformator EI igitur ita designatur ut regulatio definita habeatur, ut output ad valorem destinatum sub onere specificato perveniat. Petitiones quotarum indicare debent utrum tensio requisita sit valor ad nullum onus an ad onus plenum.
Sic, si ad 50/60 Hz designatus et notatus est. Transformator ad 50 Hz designatus generaliter ad eandem tensionem ad 60 Hz operari potest, secundum specificatio approbata. Transformator ad 60 Hz tantum non debet ad 50 Hz uti sine recensione ab ingeniario, quia minor frequencia fluxum in nucleo augit et excesse currentem atque calorem causare potest.
Yes. Series/parallel primaries can support two mains ranges, while multi-tap windings can accommodate several nominal input voltages. ECKO defines the lead colours, terminal numbers and connection diagram to prevent incorrect field wiring.
Yes. Multiple isolated secondaries, centre-tapped outputs and series/parallel windings are available. The current, regulation and isolation requirement for each output must be specified because simultaneous loading affects the thermal and voltage design.
Hum is addressed through appropriate flux density, consistent lamination assembly, secure core clamping, controlled mounting and optional varnish impregnation. The equipment design also matters: DC on the mains, waveform distortion, loose panels and rigid mounting to a resonant chassis can increase audible noise.
Ascensio temperaturae pendet ex amissione cupri, amissione nucleo, profilo oneris, frequentia, temperatura ambienti, fluxu aeris in incloso, positione montandi et fontibus caloris proximis. Verificari debet ad onus nominale definitum et conditionem installationis. Classis insulationis est aestimatio systematis materialis; non est substitutum pro specificando temperatura operationis acceptabili.
Ita. Indicate voltam mensurationis, frequentiam, conditionem ambientem et limitem acceptanceis. Tunc gradus nucleo, magnitudo stratae, spires et densitas fluxus operationis optimizari possunt. Limites strictiores magnitudinem, usum cupri aut pretium augere possunt, ideo debent reflectere requisita realia systematis.
Yes, when inductance is a required control parameter. The drawing must define which winding is measured, how other windings are connected, and the test frequency, voltage, and instrument condition. For a mains EI transformer, no-load current and loss at rated voltage are often more meaningful production controls than a small-signal inductance reading alone.
Inrush depends on core flux, switching phase, remanence, mains impedance, and connected rectifier capacitors. ECKO can optimize the magnetic design and provide engineering data, while high-power systems may also require an NTC thermistor, pre-charge resistor, relay bypass, or controlled zero-crossing strategy in the equipment.
Un scut electrostatic est normaliter plasatus inter primarium et secundarium pro reducendo accoplationem de rumore capacitivum et requirit connexionem ad terram definite. Un scut magnetic o fasciculus de fluxus est intendit pro reducendo campum magneticum vagum. Ili solvunt problemas differentes e debent seligeri ex exigentias de EMC o rumore del equipamento.
Non automatice. Un transformer standard EI necessita protectione correcte valutate in primario e/vel secundario in equipamento finitum. Fusibiles termicos, protectores reinitiabilis o disignos limitatos per impedantia posse considerari, sed performance contra corto circuitu debe esse explicitemente ingeniate e verificate pro standard requirite.
Non. Secundaria transformatoris praebet correntem alternam (AC). Onus directum (DC) requirit rectificationem et saepe filtrationem aut regulationem. Da, quaeso, topologiam rectificatoris, valorem capacitatis, voltatum DC postulatum et correntem DC, quia correns RMS secundaria potest esse multo maior quam correns output DC.
Saepe, ita est, post verificatio. Mitte descriptum existens aut exemplar una cum connexionibus, onere nominato, centris fixationis, altitudine maxima, particularibus ductuum aut terminalium, et approbationibus postulatis. ECKO examinabit compatibilitatem electricam, non solum dimensiones imitando.
Ita. Da descriptionem PCB aut dimensiones Gerber, coordinatas pinorum, magnitudines foraminum, aream interdictam, altitudinem maximam et attributionem pinorum praefertam. Descriptio dispositionis pinorum approbanda est ante fabricam utensiliorum aut productionem exemplarium.
Transformator cum structura aperta non est per se aqua-protegendum. Pro locis exterioribus, ubi condensatio accidit aut ubi contaminatio praesens est, necessarium est clausum cum indice protectionis (IP), encapsulatio, stratum protectivum, ferramenta resistentia contra corrosionem et idoneae conductores. Totum clausum apparatus et modus installationis considerandi sunt.
Transformatores EI in productione testationem dielectricam sustinendam 100% recipere possunt ad tensionem, tempus et limitem currentis deperditionis definitos in specificatio approbata. Gradus testationis aptus esse debet pro systemate insulationis et pro norma securitatis applicabili; non debet ex alio modello transformatoris non affini transcribi.
ECKO potest adiuvare conceptiones utentis materiales et exigentias constructionis applicabiles. Tamen approbationes sunt specificae pro singulis modellis et applicationibus. Confirmare oportet normam requiritam, categoriam producti finalis, mercatum et an necesse sit fasciculus componentis recognitus ab agencia an certificatio pro projecto ante citationem.
Transformatores EI offerunt constructionem flexibilem bobinae, conceptiones multiplex-vindicationis directas et optiones montandi practicas. Transformatores toroidales saepe sunt minores eadem potestate et possunt habere campum magneticum dispersum inferiorem, sed possunt habere inrusionem superiorem et alias conditiones montandi. Optima electio pendet a magnitudine, strepitu, campo fuga, impetu, pretio et exigentiis coniunctionis.
Provide input voltage and frequency, all output voltages and currents, load type, duty cycle, ambient temperature, size and mounting limits, lead or terminal requirements, insulation and test requirements, applicable standard, target quantity and any existing drawing or sample. Sample timing is then confirmed according to design complexity and material availability.
Send your transformer specification, equipment load, drawing or sample. ECKO will review electrical performance, thermal margin, construction, compliance and production feasibility before quoting.
Send Your Requirements
Fortis facultas designandi et evolvendi, nostra cohors R&D, plus quam 20 annos experientiae in industria, solutiones completas praebemus. Facimus exemplaria celeriter, celerrime die uno.
Nostra flexibilis productio et periti operarii, exemplar confici potest in 1-3 diebus, ordo infra 10000pcs tradier possit in 10-20 diebus, negotiabile secundum casus.
inspectio et examinatio 100% ante traditionem, producta certificationes CE/ROHS/CUL obtinuerunt, praestatur qualitas biennalis.
Clientes globales, nullum tempus obstaculum. Celeriter iuvamus in ordinibus, productione, technicis et quaestionibus. Continge nos aut visita fabricam nostram.