1000VA Toroidal Transformer with Low EMI for Power Amplifier
OEM 1000VA Toroidal Transformer for Hi-Fi Audio Amplifiers
| Potentia Aestimata | 1500VA |
| Input | 110V–240V AC |
| Productio | 50V-0-50V AC or Customized |
| Frequency | 50/60Hz |
| Volvenda | Copper |
| Insulatio | Classis B aut ad usum specialem |
| Applicatio | Tensio/Amplificatores |
| Adaptatio ad mensuram | Tensio, dimensiones, fili, scutum |
- Conspectus
- Producta Commendata
|
Parvum Magnitudo Plurimi toroides sunt minores quam suae comparationes E-I. Designeres electrici et mechanicis appretiant compactas dimensiones toroidis. Illi sunt praesertim apti ubi parva altitudo est consideratio.
|
INFIMA CAMPI MAGNETICI FUGACIS Toroides non habent interstitia aerea: primariae et secundariae uniformiter circum totam coram sunt convolutae. Propter hoc, toroides emittunt valde parvas campos magneticos radiatos. Hoc facit toroidem idealem pro applicationibus quae circuitus altissimae sensibilitatis involvunt.
|
Alta efficientia Propter suam unicum constructionem, toroides typice sunt inter 15 et 30% efficaciores quam typus conventionalis. Ut regula; quanto maior transformer, tanto efficacior fit.
|
|
INFIMUM SONITUM MECHANICUM Corpus toroidis formatum est ex uno unico fasciculo ferri silicii electrici gradus orientati graminis, dense convolutum in formam moli horologii, cum extremis loco puncto-saldata. Filum cupri convolvitur super pelliculam polyesteream, formans unitatem silentem et stabilem.
sine usu glutinorum aut vernicium nocivorum ambienti.
|
Dimensiones Flexibiles Augmenting the advantages of low weight and small size is the flexibility to vary dimensions. Because ECKO is not
tied down to core caps or lamination sizes, the height and diameter of our toroids may be economically varied to accommodate equipment design requirements.
|
PAUCA GRAVITAS Because they are more efficient, toroids can be up to 50% lighter (depending on power rating) than conventional laminated transformers. Low weight simplifies end-product design by reducing mounting hardware and supporting enclosure requirements.
|
|
PAUCO LABORE SINE ONERE AMISSA
Compared to conventional E-I transformers, toroids exhibit extremely low no-load losses. In applications where a circuit is in a “stand-by” mode for long periods, the potential cost reduction for
potestate significans esse potest, interdum 80-90%.
|
TEMPERATURA MINIMA OPERATIONIS Since most of the losses in a toroid are in the copper wire, the toroid cools off quicker than the conventional E-I type with more iron. At half the load, the toroid’s temperature rise is only about 30% of what it is at full load.
|
FACILIS MONTATIO Unus scrua centralis simpliciter et celeriter toroidem adfigit, evitans onerosam conceptionem mechanicam et problemata practica quae ad laminata E-I conventionalia pertinent transformatores ... and three screws are eliminated at assembly!
|




